Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Info

Example relative reference range as -5 percentage point with reference base 90% for oxygen saturation measurement

The oxygen saturation measurement unit is expressed as percent (system=http://unitsofmeasure.org, code=%), the reference base likewise and in this case with a value of 90.

A red alarm relative reference range given as -5 percentage point would be given by a SimpleQuantity for the reference range’s low element with:

  • value=-5

  • unit=percentage point

  • system=http://ehealth.sundhed.dk/cs/ehealth-unit-code

  • code=percentagepoint

Thus, the rule would treat an Observation with value 85% as a red alarm case for this relative reference range and current choice of reference base with value 90%.

The rule handles situations as follows:

Situation

Handling by setting up instructions causing creation of Task

Neither reference base nor relative reference range(s) found

Task:

  • .category with .code = MeasurementForAssessmentNotTriaged, .system = http://ehealth.sundhed.dk/cs/task-category, .display = Need assessment of measurement where triage was not performed during automated processing

  • .description = Måling til vurdering, hvor triagering ikke er udført af automatiseret behandling

  • .restrictionCategory with .code = measurement-monitoring, system = http://ehealth.sundhed.dk/cs/restriction-category, .display = Monitoring of measurement(s)

  • .priority = routine

  • .focus = reference to measurement being processed, for instance Observation, QuestionnaireResponse or Media

No additional task.

No reference base found

Task:

  • .category with .code = RefBaseNeeded, .system = http://ehealth.sundhed.dk/cs/task-category, .display = Missing in force reference base required for automatic processing

  • .description = Mangler gældende referenceværdi påkrævet for automatisk behandling

  • .restrictionCategory with .code = measurement-monitoring, system = http://ehealth.sundhed.dk/cs/restriction-category, .display = Monitoring of measurement(s)

  • .priority = routine

  • .focus = reference to ServiceRequest referenced by the measurement being processed

No relative reference range found

Task:

  • .category with .code = RefRangeNeeded, .system = http://ehealth.sundhed.dk/cs/task-category, .display = Missing reference range required for automated processing

  • .description = Mangler grænseværdi påkrævet for automatisk behandling

  • .restrictionCategory with .code = measurement-monitoring, system = http://ehealth.sundhed.dk/cs/restriction-category, .display = Monitoring of measurement(s)

  • .priority = routine

  • .focus = reference to ServiceRequest referenced by the measurement being processed

Assessment of TeleCare Nord COPD Questionnaire

...