Info |
---|
Example relative reference range as -5 percentage point with reference base 90% for oxygen saturation measurement The oxygen saturation measurement unit is expressed as percent (system=http://unitsofmeasure.org , code=% ), the reference base likewise and in this case with a value of 90. A red alarm relative reference range given as -5 percentage point would be given by a SimpleQuantity for the reference range’s low element with: Thus, the rule would treat an Observation with value 85% as a red alarm case for this relative reference range and current choice of reference base with value 90%. |
The rule handles situations as follows:
Situation | Handling by setting up instructions causing creation of Task |
---|
Neither reference base nor relative reference range(s) found | Task: .category with .code = MeasurementForAssessmentNotTriaged , .system = http://ehealth.sundhed.dk/cs/task-category , .display = Need assessment of measurement where triage was not performed during automated processing
.description = Måling til vurdering, hvor triagering ikke er udført af automatiseret behandling
.restrictionCategory with .code = measurement-monitoring , system = http://ehealth.sundhed.dk/cs/restriction-category , .display = Monitoring of measurement(s)
.priority = routine
.focus = reference to measurement being processed, for instance Observation, QuestionnaireResponse or Media
| No additional task. |
No reference base found | Task: .category with .code = RefBaseNeeded , .system = http://ehealth.sundhed.dk/cs/task-category , .display = Missing in force reference base required for automatic processing
.description = Mangler gældende referenceværdi påkrævet for automatisk behandling
.restrictionCategory with .code = measurement-monitoring , system = http://ehealth.sundhed.dk/cs/restriction-category , .display = Monitoring of measurement(s)
.priority = routine
.focus = reference to ServiceRequest referenced by the measurement being processed
|
No relative reference range found | Task: .category with .code = RefRangeNeeded , .system = http://ehealth.sundhed.dk/cs/task-category , .display = Missing reference range required for automated processing
.description = Mangler grænseværdi påkrævet for automatisk behandling
.restrictionCategory with .code = measurement-monitoring , system = http://ehealth.sundhed.dk/cs/restriction-category , .display = Monitoring of measurement(s)
.priority = routine
.focus = reference to ServiceRequest referenced by the measurement being processed
|
Assessment of TeleCare Nord COPD Questionnaire
...